Trinity College Dublin has entered into an agreement with Optics11 Life B.V. for the delivery of an electromechanical engineered heart tissue bioreactor, with a total value of 187,500 EUR. The bioreactor platform must be capable of culturing 3D in vitro engineered cardiac muscle tissues, providing tunable electrical stimulation, monitoring at up to 15 kHz, and measuring contractile forces with a sensitivity of 1 micro Newton. It should culture volumes of 50 microlitres or less with a maximum of 500,000 cells, be suited for a 24-well plate format with future upgrade potential to 96 and/or 384 well plates, and include user-friendly software for custom electrical stimulation and contraction force protocols. The contract duration is 4 years. One bid was received for this contract.
Laboratorie-, optisk- og presisjonsutstyr
Result
- Optics11 Life B.V.Winner
- 1Number of tenders received
- €187,500Contract value
Previous winners
Who are you up against?
The suppliers who have won similar contracts at Trinity College Dublin the University of Dublin_336
Will you bid?
The agent sets up the bid and writes the first draft. Free for 14 days.
Award Criteria
Description
Cost @ 25%
Source
No source found in the documents. Check the weight against the tender documents.
Description
Quality @ 75%
Source
No source found in the documents. Check the weight against the tender documents.
From the notice
Cell culture compatible bioreactor platform capable of culturing 3D in vitro engineered muscle tissues (specifically cardiac) that can provide tunable electrical stimulation to tissues while allowing contraction of the tissue. The system should be able to monitor the system up to a speed of 15 kHz and have the capacity to measure contractile forces (inferred by contraction-enabled movement of supporting pillar structures) up to a sensitivity of 1 micro Newton. It should be able to culture voumes of 50 microlitres or less with a maximum of 500,000 cells present in the EHT. The system should be suited for a 24-well plate format with potential to upscale to 96 and/or 384 well plates with future upgrades. The system should be coupled with user-friendly software . It is necessary to program custom electrical stimulation and contraction force protocols per column in a 24 well plate by adjusting parameters such as smplitude, voltage, pulse width and the duration of the stimulation phase to create twitc or tetanic muscle stimuli for muslce tissue training.
Contact
mireilly@tcd.ie- ResultType
- DublinLocation
- 38000000Main codeLaboratory, optical and precision equipments (excl. glasses)
- 38300000Measuring instruments38340000Instruments for measuring quantities38423000Pressure-measuring equipment38424000Measuring and control equipment38434500Biochemical analysers38434540Biomedical equipment38540000Machines and apparatus for testing and measuring38570000Regulating and controlling instruments and apparatus