Find

  • All tenders
Denmark: Tenders/Danish Decommissioning/Electronic Dosimetry System incl. dosimeters and readers/terminals

Electronic Dosimetry System incl. dosimeters and readers/terminals

Published deadline passed

The published deadline has passed. For multi-stage competitions a later tender deadline may still apply — check the notice or portal for the current phase.

Deadline
Jun 10, 2025Expired
Award
Software usability, weight 20 and 5 more
Agreement
Buying goodsover 5 years

Brief

Dansk Dekommissionering trenger et elektronisk dosimetrisystem inkludert dosimetre og lesere/terminaler for en kontrakt over 5 år, med en estimert totalverdi på 600.000 danske kroner. Systemet skal bestå av 2 lesere/terminaler og 60 dosimetre, samt nødvendig programvare og annet maskinvare, og skal leveres i Østsjælland. Formålet med anskaffelsen er å sikre strålingsovervåking av både interne og eksterne ansatte, hvor dosimetre brukes til å sjekke inn og ut av radiologisk klassifiserte områder, med data lagret i en database for overvåking og rapportering. Tildelingskriteriene inkluderer pris (40 %), programvarebrukervennlighet (20 %), maskinvarebrukervennlighet (15 %), dosimetervekt (10 %), produktstandarder (5 %), kompatibilitet med eksisterende dosimetre (5 %), og systemintegrasjon med annet dosimetriutstyr (5 %). Dosimetre må være i samsvar med IEC 61526-standarder, og det er en fordel med kompatibilitet til eksisterende MGP DMC 2000 dosimetre.

Register interest

Previous winners

  • Who are you up against?

    The suppliers who have won similar contracts at Danish Decommissioning

Will you bid?

The agent sets up the bid and writes the first draft. Free for 14 days.

Award Criteria

  • Description

    The price, given as the total sum of the tender given in Appendix 2 – Pricelist, weighs in with 40 % of the total assessment. 5 points is awarded to the lowest total award sum and 1 point is awarded to the highest total award sum. Remaining tenders will be rated proportionally and awarded 2 to 4 point given the total award sum. However, any tender where the total award sum is equal to or less than the estimated total contract value of 600.000 DKK, cannot be awarded less than 3 points.

    Source

    No source found in the documents. Check the weight against the tender documents.

  • Description

    The software usability delivered with the electronic dosimtery system and dosimeters will be weigthed with 20 % of the total assessment (100%). The software interfaces must be logically structured and easy to understand without requiring extensive training. Tenders will be weighted more positively the more intuitive and easy to use the software is the users, especially with regard to reporting tools and dashboards. 5 points will be awarded to the tender that is rated with the highest level of software usability and 1 point will be awarded to tender with the lowest rated software usability. Remaining tenders will proportionally be awarded 2 to 4 points given the rated level of software usability.

    Source

    No source found in the documents. Check the weight against the tender documents.

  • Description

    The hardware usability on the electronic dosimetry system and dosimeters will be weighted with 15 % of the total assessment (100%). Tenders will be weighed more positively the more intuitive and easy to use the hardware is to the users, especially with regard to display readability and the ability to easy and fast read and transfer data. 5 points will be awarded to the tender that is rated with the highest level of hardware usability and 1 point will be awarded to tender with the lowest rated level of hardware usability. Remaining tenders will proportionally be awarded 2 to 4 points given the rated level of hardware usability.

    Source

    No source found in the documents. Check the weight against the tender documents.

  • Description

    The dosimeters must be easy to handle and the weight of each dosimter will be weighted with 10 % of the total assessment (100 %). Each dosimeter must not weigh more than 200 g (battery and clips included), but the lower weight of each dosimeter the more positively the tender will be rated. 5 points will be awarded to the tender with the lowest weight of each dosimeter and 1 point will be awarded to the tender with the highest weight (max 200 g). Remaining tenders will proportionally be awarded 2 to 4 points given the documented weight of each dosimeter.

    Source

    No source found in the documents. Check the weight against the tender documents.

  • Description

    Dosimeters compliant to IEC 61526 standards or similar are preferred and will be weighted with 5 % of the total assessment (100 %). 5 points will be awarded to tenders who can document complete compliance to IEC 61526 standards or similar and 1 point will be awarded to tenders who cannot document any compliance to IEC 61526 standards or similar. Remaining tenders will be rated proportionally with 2 to 4 point given the documented level of compliance.

    Source

    No source found in the documents. Check the weight against the tender documents.

  • Description

    The level of compatibility of the readers/terminals and software to the existing dosimeters at the Contracting Authority (MGP DMC 2000) will be weighted with 5 % of the total assessment (100%). Tenderers will be weighed more positively the more compatible the product is. 5 points will be awarded to tenders who can document complete compatibility to MGP DMC 2000 and 1 point will be awarded to tenders who cannot document any compatibility. Remaining tenders will be rated proportionally with 2 to 4 point given the documented level of compatibility.

    Source

    No source found in the documents. Check the weight against the tender documents.

  • Description

    The dosimeters must as a minimum be able to register photons (Hp10); however, it would be an advantage, if electron and/or neutron dosimetry equipment (modules or extra dosimeters) could be integrated to the system at a later point. This criteria will be weighted with 5 % of the total assessment (100 %). 5 points will be awarded to tenders who can support fully flexible integration of electron and neutron dosimetry equipment and 1 point will be awarded to tenders who are not able to support any integration of electron and/or neutron dosimetry equipment at a later point. Remaining tenders will be rated proportionally with 2 to 4 point given the documented capability of integration.

    Source

    No source found in the documents. Check the weight against the tender documents.

From the notice

  • In order to secure the radiation monitoring of internal as well as external staff a new electronic dosimetry system is required, in which the staff can pick up an electronic dosimeter, check in through a dosimeter reader/terminal where a identification is needed, before entering radiologically classified areas. When staff is leaving radiologically classified areas, a check out (read out) should likewise take place at the dosimeter reader/terminal before the dosimeter is put back on a wall rack. Data from the transit (employee identification, time of entering and leaving a classified area etc.) must be saved on a database and a monitoring and report software should be used to monitor and report the doses. The electronic dosimetry system must consist of 2 readers/terminals and 60 dosimeters including necessary software and other hardware. A full description of the procedure and requirements for this advertisement is found in the attached documents.Main features of the procedureThe contracting authority advertises the task in accordance with Title IV of the Danish Public Procurement Act, as the contracting authority assesses that this contract has a certain cross-border interest. The material that forms the basis for the submission of tenders as well as information on the procedure are attached to this announcement. The tenderer must be aware the tender must prepared in writing according to the Advertisement letter attached to this announcement.

  • Contact

    Dansk Dekommissionering, Anders Dybdahl Bluhmeanblu@dekom.dk
  • Type
    Competition
  • Location
    Østsjælland
  • Main code
    Apparatus for measuring radiation
    38341000

Similar active competitions

  • Danish Decommissioning

    Laboratorie-, optisk- og presisjonsutstyr

    Procurement of Radiation Contamination Detection Monitors and Associated Goods, Services and Maintenance

    Danish Decommissioning needs a framework agreement for three hand-and-foot radiation contamination monitors, including accessories, services and maintenance, with options to purchase three additional monitors on the same basis; the optional monitors are not guaranteed purchases. The agreement covers 4 years, has a maximum total value of EUR 375,000, and delivery is in eastern Zealand, Denmark. Offers are evaluated on price.

    Framework agreement
    Nov 23, 2026(0 days)
    €375,000
  • Societatea Nationala NUCLEARELECTRICA S.A.

    Monitoare interzonale pentru controlul contaminarii intregului corp, in 2 pasi - CR # 44869

    Societatea Națională Nuclearelectrica S.A. are nevoie, pentru o perioadă de 1 an, de furnizarea, instalarea, punerea în funcțiune și testarea a 6 monitoare interzonale pentru controlul contaminării întregului corp, în Constanța, cu o valoare totală maximă de 670.500 de euro. Echipamentele trebuie să includă cititor RFID încorporat sau dedicat și să detecteze contaminarea radioactivă alfa și beta; minimumul acceptat este de 10 detectori, iar activitatea minimă detectabilă în cel mult 5 secunde trebuie să fie sub 24 Bq/100 cm² pentru alfa și sub 80 Bq/100 cm² pentru beta. Ofertele sunt evaluate după preț (55%), numărul de detectori (15%), performanța AMD (15%) și garanția echipamentelor (15%); pentru punctajul maxim la garanție se solicită cel puțin 36 de luni. Calificarea presupune certificare ISO 9001 sau echivalent și referințe din ultimii 3 ani pentru livrări de echipamente de monitorizare a radiațiilor în valoare cumulată de minimum 95.000 de euro fără TVA.

    Competition
    Dec 22, 2026(29 days)
    €670,500
  • FAIR - Facility for Antiproton and Ion Research in Europe GmbH

    Laboratorie-, optisk- og presisjonsutstyr

    Passive Neutron Dosimeters

    FAIR – Facility for Antiproton and Ion Research in Europe GmbH needs 100 passive neutron dosimeters for environmental monitoring at its facility in Darmstadt, Germany. The award is based on price (30%) and design/manufacturing method (70%): dosimeters manufactured without adhesive receive the maximum design score, while adhesive assembly receives a lower score.

    Competition
    Dec 18, 2026(25 days)