Flexing Culture Membrane Bioreactor for Trinity College Dublin
Awarded
The competition has ended and a winner has been selected.
- Deadline
- 8. juniExpired
- Award
- Quality, weight 75
Brief
Trinity College Dublin the University of Dublin_336 has entered into an agreement with Dunn Labortechnik GmbH for the delivery of a computer-controlled bioreactor capable of applying cyclic or static tensile strains to cells cultured in vitro using regulated vacuum and positive air pressure. The system should be capable of simulating in vivo tissue strains and frequencies to cells from muscle, lung, heart, bone, blood vessels and tendon. Multiple frequency, amplitude and waveform changes must be able to be programmed in one regimen with waveforms ranging from static, sinusoidal, cardiac, triangular, square and some custom waveforms. It should be suitable for a standard 6-well cell culture plate configuration with the option to actuate more than one well-plate simultaneously. The contract has a duration of 3 years and a total value of 65,000 EUR. One bid was received.
Laboratorie-, optisk- og presisjonsutstyr
Result
- Dunn Labortechnik GmbHWinner
- 1Number of tenders received
- €65,000Contract value
Previous winners
Who are you up against?
The suppliers who have won similar contracts at Trinity College Dublin the University of Dublin_336
Will you bid?
The agent sets up the bid and writes the first draft. Free for 14 days.
Award Criteria
Description
Cost @ 25%
Source
No source found in the documents. Check the weight against the tender documents.
Description
Quality @ 75%
Source
No source found in the documents. Check the weight against the tender documents.
From the notice
A computer-controlled bioreactor is required capable of applying cyclic or static tensile strains to cells cultured in vitro using regulated vacuum and positive air pressure. The system should be capable of simulating in vivo tissue strains and frequencies to cells from muscle, lung, heart, bone, blood vessels and tendon. Multiple frequency, amplitude and waveform changes must be able to be programmed in one regimen with waveforms ranging from static, sinusoidal, cardiac, triangular, square and some custom waveforms. Should be suitable for a standard 6-well cell culture plate configuration with the option to actuate more than one well-plate simultaneously.
Contact
mireilly@tcd.ie- ResultType
- DublinLocation
- 38000000Main codeLaboratory, optical and precision equipments (excl. glasses)
- 38300000Measuring instruments38340000Instruments for measuring quantities38423000Pressure-measuring equipment38424000Measuring and control equipment38434500Biochemical analysers38434540Biomedical equipment38540000Machines and apparatus for testing and measuring38570000Regulating and controlling instruments and apparatus