FORNITURA DI STRUMENTAZIONI DA LABORATORIO DA INSTALLARE PRESSO LUOC CLINICA DI MEDICINA DI LABORATORIO E DI PRECISIONE PER I PRESIDI OSPEDALIERI DI ANCONA E OSIMO
Awarded
The competition has ended and a winner has been selected.
- Deadline
- Jun 11, 2025Expired
- Award
- Numero massimo di fluorescenze, weight 1.06 and 53 more
Brief
FORNITURA DI STRUMENTAZIONI DA LABORATORIO DA INSTALLARE PRESSO LUOC CLINICA DI MEDICINA DI LABORATORIO E DI PRECISIONE PER I PRESIDI OSPEDALIERI DI ANCONA E OSIMO
Laboratorie- og analyseutstyr
Result
- BIOMEREIUX ITALIA SPAWinner
- Beckman Coulter S.r.l.Winner
- DASIT S.P.A.Winner
- LABORMED SRLSWinner
- 1Number of tenders received
- €360,185Contract value
Previous winners
Who are you up against?
The suppliers who have won similar contracts at INRCA Istituto di Ricovero e Cura a Carattere Scientifico
Will you bid?
The agent sets up the bid and writes the first draft. Free for 14 days.
Award Criteria
Description
Punteggio prezzo - formula come da disciplinare
Source
No source found in the documents. Check the weight against the tender documents.
Description
Numero massimo di fluorescenze con marcatura CE-IVD implementabili con aggiornamento futuro
Source
No source found in the documents. Check the weight against the tender documents.
Description
Laser a stato solido non veicolati alla cella a flusso (trasmissione in aria) per incrementarne la potenza in zona di intersezione con il campione
Source
No source found in the documents. Check the weight against the tender documents.
Description
Segnali di tutte le fluorescenze raccolti su fotodiodi ad alta sensibilità
Source
No source found in the documents. Check the weight against the tender documents.
Description
Risoluzione delle fluorescenze misurata in canali su dati compensati e non compensati. Intervallo di risoluzione da 0 a 16277216 equivalente a 24 bit e 7 decadi logaritmiche
Source
No source found in the documents. Check the weight against the tender documents.
Description
Potenza dei laser su tutte le lunghezze donda espressa in mW. Si precisa che il confronto verrà fatto sommando le potenze dei singoli laser
Source
No source found in the documents. Check the weight against the tender documents.
Description
Volume morto (in microlitri) di campione nella provetta (residuo non campionabile)
Source
No source found in the documents. Check the weight against the tender documents.
Description
Conte assolute in singola piattaforma con biglie in formato liquido da dispensare al campione
Source
No source found in the documents. Check the weight against the tender documents.
Description
Funzione grafica dedicata per la modifica manuale dei valori di compensazione direttamente sui citogrammi dellesperimento durante lacquisizione del campione senza perdita degli eventi già acquisiti
Source
No source found in the documents. Check the weight against the tender documents.
Description
Impostazione manuale del parametro threshold direttamente sui citogrammi dell'esperimento tramite funzione grafica dedicata
Source
No source found in the documents. Check the weight against the tender documents.
Description
Dimensioni analizzatore ridotte: somma delle tre dimensioni
Source
No source found in the documents. Check the weight against the tender documents.
Description
Agitazione vortex applicabile singolarmente sul campionatore per ogni singola provetta prima dell'aspirazione ed analisi del campione, relazionare in maniera dettagliata la modalità
Source
No source found in the documents. Check the weight against the tender documents.
Description
Possibilità di utilizzare piastrine monouso
Source
No source found in the documents. Check the weight against the tender documents.
Description
Dimensioni e peso ridotti (relazionare)
Source
No source found in the documents. Check the weight against the tender documents.
Description
Caricamento continuo delle piastrine contenenti i campioni, con possibilità di caricamento prioritario di una piastrina in caso di urgenza
Source
No source found in the documents. Check the weight against the tender documents.
Description
Gestione unificata delle piastrine e dei pannelli per antibiogramma, con integrazione completa dei risultati in un unico software (interfaccia unica)
Source
No source found in the documents. Check the weight against the tender documents.
Description
Al fine di poter garantire la massima ottimizzazione dei tempi, il sistema deve disporre della possibilità, in caso di necessità, di poter operare da più postazioni di preparazione in contemporanea per gestire simultaneamente i campioni di identificazione in spettrometria di massa ed antibiogramma (relazionare)
Source
No source found in the documents. Check the weight against the tender documents.
Description
Matrice e ulteriori reattivi necessari pronti all'uso
Source
No source found in the documents. Check the weight against the tender documents.
Description
Il sistema deve essere dotato di software di gestione che permetta la programmazione del Maldi-ToF e dello strumento per antibiogrammi tramite un'unica interfaccia. Tale software deve ricevere i dati dellidentificazione e antibiogramma, applicare le regole del sistema esperto in dotazione allo strumento per antibiogramma e poi trasmettere il risultato completo (MIC e interpretazione) e validato dal sistema esperto al LIS. Il software deve disporre anche di un sistema esperto proprio, che deve essere in grado di analizzare criticamente anche i risultati di antibiogramma e identificazione ottenuti mediante metodi manuali (relazionare)
Source
No source found in the documents. Check the weight against the tender documents.
Description
Il software deve permettere studi di epidemiologia ed essere in grado di rilevare e monitorare le infezioni spedaliere, i microrganismi alert e multiresistenti, consentendo di inviare i relativi allarmi ai reparti e alle direzioni ospedaliere (relazionare).
Source
No source found in the documents. Check the weight against the tender documents.
Description
Il sistema deve prevedere la completa compatibilità con gli strumenti per antibiogramma utilizzati dall'Ente e di proprietà dell'Ente stesso (Vitek)
Source
No source found in the documents. Check the weight against the tender documents.
Description
Punti prezzo - formula come da disciplinare di gara
Source
No source found in the documents. Check the weight against the tender documents.
Description
Ingrandimento massimo del microscopio in dotazione allo strumento
Source
No source found in the documents. Check the weight against the tender documents.
Description
Velocità di acquisizione della videocamera sCMOS
Source
No source found in the documents. Check the weight against the tender documents.
Description
Termostatazione del campione
Source
No source found in the documents. Check the weight against the tender documents.
Description
Equipaggiamento dello strumento con laser 488nm e corrispondente filtro long pass 500nm
Source
No source found in the documents. Check the weight against the tender documents.
Description
Presenza di un sistema di pompaggio del campione attivo durante l'acquisizione del segnale
Source
No source found in the documents. Check the weight against the tender documents.
Description
Sistema dotato di software in grado di rilevare il drift delle particelle non correlabile al moto browniano
Source
No source found in the documents. Check the weight against the tender documents.
Description
Concentrazione minima (particelle/mL) delle particelle in camera di rilevazione
Source
No source found in the documents. Check the weight against the tender documents.
Description
Software in grado di restituire feedback sulla qualità del dato tramite intelligenza artificiale
Source
No source found in the documents. Check the weight against the tender documents.
Description
Software in grado di rilevare e quantificare il photobleaching del fluoroforo
Source
No source found in the documents. Check the weight against the tender documents.
Description
Possibilità di aprire completamente la cella per una pulizia meccanica delle superfici a contatto con il campione
Source
No source found in the documents. Check the weight against the tender documents.
Description
Possibilità di osservare la fase di tracking delle particelle e i singoli tracciati nello spazio 2D tramite software
Source
No source found in the documents. Check the weight against the tender documents.
Description
Punti prezzo - formula come da disciplinare
Source
No source found in the documents. Check the weight against the tender documents.
Description
Supporto LIS bidirezionale mediante protocollo ASTM
Source
No source found in the documents. Check the weight against the tender documents.
Description
Compatibilità con i preparati ematologici prodotti dallo strisciatore/coloratore automatizzato in uso presso listituto (Sysmex SP-50) senza necessità di ulteriori operazioni da parte delloperatore
Source
No source found in the documents. Check the weight against the tender documents.
Description
Compatibilità con strisci di sangue prodotti manualmente
Source
No source found in the documents. Check the weight against the tender documents.
Description
Produttività massima del sistema, misurata in termini di numero di vetrini letti per ora
Source
No source found in the documents. Check the weight against the tender documents.
Description
Capacità di archiviazione locale dei vetrini, misurata in base al numero di preparati archiviabili su memoria locale
Source
No source found in the documents. Check the weight against the tender documents.
Description
Possibilità di accedere allinterfaccia di comando dello strumento mediante connessione remota (allinterno della Intranet aziendale) per la revisione a distanza dei preparati
Source
No source found in the documents. Check the weight against the tender documents.
Description
Presenza di un archivio di immagini con le quali l'operatore possa confrontare le immagini digitalizzate
Source
No source found in the documents. Check the weight against the tender documents.
Description
Possibilità di riconoscimento e lettura da parte del software degli aggregati piastrinici
Source
No source found in the documents. Check the weight against the tender documents.
Description
Numero di diverse popolazioni di leucociti che possono essere lette e pre-classificate dallo strumento
Source
No source found in the documents. Check the weight against the tender documents.
Description
Dimensioni analizzatore ridotte: somma delle tre dimensioni.
Source
No source found in the documents. Check the weight against the tender documents.
Description
Presenza di un sistema integrato di messaggistica fra gli utenti utilizzatori dei congelatori
Source
No source found in the documents. Check the weight against the tender documents.
Description
Presenza di interfaccia USB per poter scaricare i dati di registrazione e allarme degli ultimi 10 anni
Source
No source found in the documents. Check the weight against the tender documents.
Description
Presenza di un sistema di chiusura a leva per ciascun controsportello interno
Source
No source found in the documents. Check the weight against the tender documents.
Description
Tempo di riscaldamento (da -85°C a 0°C, con freezer pieno per 2/3) in caso di mancanza di alimentazione elettrica
Source
No source found in the documents. Check the weight against the tender documents.
Description
Presenza di sistema di isolamento con pannelli sottovuoto VIP ad alta efficienza e poliuretano espanso, con spessore non inferiore a 130 mm
Source
No source found in the documents. Check the weight against the tender documents.
Description
Livello di rumorosità medio, espresso in dbA
Source
No source found in the documents. Check the weight against the tender documents.
Description
Consumo energetico giornaliero con temperatura di esercizio di -80°C, espresso in kWh
Source
No source found in the documents. Check the weight against the tender documents.
Description
Presenza di display touchscreen che mostri la temperatura di esercizio con precisione di 0.1°C
Source
No source found in the documents. Check the weight against the tender documents.
Description
Protezione dellaccesso alle impostazioni del frigocongelatore mediante password da immettere sul display frontale
Source
No source found in the documents. Check the weight against the tender documents.
Description
Presenza di sistema di refrigerazione con due impianti indipendenti, ciascuno dotato di compressore ermetico. In caso di guasto di un compressore, laltro dovrà mantenere una temperatura di esercizio <= -70°C
Source
No source found in the documents. Check the weight against the tender documents.
Description
Punti prezzo - formula come da documentazione di gara
Source
No source found in the documents. Check the weight against the tender documents.
From the notice
FORNITURA DI STRUMENTAZIONI DA LABORATORIO DA INSTALLARE PRESSO LUOC CLINICA DI MEDICINA DI LABORATORIO E DI PRECISIONE PER I PRESIDI OSPEDALIERI DI ANCONA E OSIMO
Contact
inrca.gare@pec.it- ResultType
- AnconaLocation
- 38430000Main codeDetection and analysis apparatus