Search
  • Search


    High-throughput microelectrode array (MEA) and impedance equipment

    University of Helsinki

    High-throughput microelectrode array (MEA) and impedance equipment

    1. Supplier selection

      Feb 16, 12:00 AMFebruary 16, 2026 12:00 AM
    2. Result notice published

      Feb 18, 7:47 AMFebruary 18, 2026 7:47 AM
    3. Change in result

      Feb 26, 6:23 AMFebruary 26, 2026 6:23 AM

    Brief

    Finland: Tenders/University of Helsinki/High-throughput microelectrode array (MEA) and impedance equipment

    Cancelled

    The competition has been cancelled.

    Qualification deadline
    Feb 25,Expired
    Procedure
    Without prior noticeTwo stages
    Agreement
    Buying goods

    Brief

    University of Helsinki has entered into an agreement with Axion Biosystems for the delivery of high-throughput microelectrode array (MEA) and impedance equipment. The equipment must enable medium to high throughput analysis with at least 96-well format capacity, measurements with several plate formats (at least 12, 24, 48, 96 wells), have over 700 measurement electrodes per MEA plate, at least 12.5 kHz data sampling frequency, the ability to induce and measure cardiac local extracellular action potentials (LEAP), monitor live cell function parameters in real time via impedance with at least 96-well plate capacity, an optogenetic stimulator, temperature and gas environment control for the measurement chamber, the possibility for a transparent sample area in wells for imaging, the possibility to use customized MEA plates, and advanced, license-free analysis software packages specifically designed for neuronal and cardiac cell analysis, cell viability, and impedance measurements.

    Laboratorie- og analyseutstyr

    Result

    TED
    • Reason for cancellation
      Besluttning av oppdragsgiveren, ikke som følge av klage på tildeling fra en tilbyder/leverandør, på grunn av tekniske eller prosessfeil
    • Number of bids
      1

    Custom Assessment Criteria

    • Get answers to your bid/no-bid criteria

      Set them up once and Cobrief answers them in every tender

    Will you bid?

    The agent sets up the bid and writes the first draft. Free for 14 days.

    Award Criteria

    • Description

      minimum quality criteria

      Source

      No source found in the documents. Check the weight against the tender documents.

    Previous winners

    • Who are you up against?

      The suppliers who have won similar contracts at University of Helsinki

    From the notice

    • Microelectrode array (MEA) systems are novel tools in electrophysiology that will help the basic and preclinical research on brain and cardiac diseases with a goal to efficiently translate preclinical research findings into efficient treatment, prevention and diagnosis. Electrophysiological techniques allow comprehensive understanding of the biological basis of functioning of these cell types in health and in pathological conditions. MEA technology is one of the core methods to study e.g. electrophysiological characteristics of neuronal and cardiac cells and their function both in normal and diseased conditions. High-throughput MEA instruments allow also drug discovery for neurological and cardiovascular diseases and investigation of novel therapeutic targets/treatments in human cell-based models in vitro. Instrument with integrated impedance technology allows also cell viability and neuro/cardio-toxicity analysis, which are highly relevant for early safety assessment of new drug leads. Minimum technical specifications required from the high-throughput microelectrode array (MEA) and impedance equipment to be purchased are: • Enables medium to high throughput analysis i.e. at least 96-well format capacity. This throughput is needed for screening compound libraries where compound stock volumes are limited. • Enables measurements with several plate formats mimicking standard well culture plates (at least 12, 24, 48, 96 well formats). This flexibility is required to enable experiments with various cell models some of which cannot be established in high-throughput format • >700 measurement electrodes per MEA plate to allow high quality data output with high number of electrodes per well • At least 12.5 kHz data sampling frequency to identify fast occurring electrophysiological events in neuronal and cardiac cells • Ability to induce and measure cardiac local extracellular action potentials (LEAP) on any and every electrode in a plate • Capable of monitoring live cell function parameters in real time including cell proliferation, cytotoxicity, cell adhesion, receptor based functional assays, immune cell killing, ADCC, viral neutralizing antibody detection, cell migration, wound healing, and barrier function through impedance with at least 96-well plate capacity • Optogenetic stimulator for customizable light stimulation • Temperature and gas environment control for measurement chamber to enable stable long-term measurements • Option for transparent sample area in wells for imaging cell growth, morphology for identification • Possibility to use customised MEA plates, e.g. organ-on-a-chip platforms for co-cultures and tissue models • Advanced, license-free analysis software packages specifically designed for neuronal and cardiac cell analysis, cell viability and impedance measurements

    • Contact

      Hankinnathankinnat@helsinki.fi
    • Type
      Result · Prequalification
    • Main code
      Laboratory, optical and precision equipments (excl. glasses)
      38000000
    • 38434540Biomedical equipment38500000Checking and testing apparatus38540000Machines and apparatus for testing and measuring