High-throughput microelectrode array (MEA) and impedance equipment
Cancelled
The competition has been cancelled.
- Qualification deadline
- Feb 25,Expired
- Procedure
- Without prior noticeTwo stages
- Agreement
- Buying goods
Brief
University of Helsinki has entered into an agreement with Axion Biosystems for the delivery of high-throughput microelectrode array (MEA) and impedance equipment. The equipment must enable medium to high throughput analysis with at least 96-well format capacity, measurements with several plate formats (at least 12, 24, 48, 96 wells), have over 700 measurement electrodes per MEA plate, at least 12.5 kHz data sampling frequency, the ability to induce and measure cardiac local extracellular action potentials (LEAP), monitor live cell function parameters in real time via impedance with at least 96-well plate capacity, an optogenetic stimulator, temperature and gas environment control for the measurement chamber, the possibility for a transparent sample area in wells for imaging, the possibility to use customized MEA plates, and advanced, license-free analysis software packages specifically designed for neuronal and cardiac cell analysis, cell viability, and impedance measurements.
Laboratorie- og analyseutstyr
Result
- Reason for cancellationBesluttning av oppdragsgiveren, ikke som følge av klage på tildeling fra en tilbyder/leverandør, på grunn av tekniske eller prosessfeil
- 1Number of bids
Custom Assessment Criteria
Get answers to your bid/no-bid criteria
Set them up once and Cobrief answers them in every tender
Will you bid?
The agent sets up the bid and writes the first draft. Free for 14 days.
Award Criteria
Description
minimum quality criteria
Source
No source found in the documents. Check the weight against the tender documents.
Previous winners
Who are you up against?
The suppliers who have won similar contracts at University of Helsinki
From the notice
Microelectrode array (MEA) systems are novel tools in electrophysiology that will help the basic and preclinical research on brain and cardiac diseases with a goal to efficiently translate preclinical research findings into efficient treatment, prevention and diagnosis. Electrophysiological techniques allow comprehensive understanding of the biological basis of functioning of these cell types in health and in pathological conditions. MEA technology is one of the core methods to study e.g. electrophysiological characteristics of neuronal and cardiac cells and their function both in normal and diseased conditions. High-throughput MEA instruments allow also drug discovery for neurological and cardiovascular diseases and investigation of novel therapeutic targets/treatments in human cell-based models in vitro. Instrument with integrated impedance technology allows also cell viability and neuro/cardio-toxicity analysis, which are highly relevant for early safety assessment of new drug leads. Minimum technical specifications required from the high-throughput microelectrode array (MEA) and impedance equipment to be purchased are: • Enables medium to high throughput analysis i.e. at least 96-well format capacity. This throughput is needed for screening compound libraries where compound stock volumes are limited. • Enables measurements with several plate formats mimicking standard well culture plates (at least 12, 24, 48, 96 well formats). This flexibility is required to enable experiments with various cell models some of which cannot be established in high-throughput format • >700 measurement electrodes per MEA plate to allow high quality data output with high number of electrodes per well • At least 12.5 kHz data sampling frequency to identify fast occurring electrophysiological events in neuronal and cardiac cells • Ability to induce and measure cardiac local extracellular action potentials (LEAP) on any and every electrode in a plate • Capable of monitoring live cell function parameters in real time including cell proliferation, cytotoxicity, cell adhesion, receptor based functional assays, immune cell killing, ADCC, viral neutralizing antibody detection, cell migration, wound healing, and barrier function through impedance with at least 96-well plate capacity • Optogenetic stimulator for customizable light stimulation • Temperature and gas environment control for measurement chamber to enable stable long-term measurements • Option for transparent sample area in wells for imaging cell growth, morphology for identification • Possibility to use customised MEA plates, e.g. organ-on-a-chip platforms for co-cultures and tissue models • Advanced, license-free analysis software packages specifically designed for neuronal and cardiac cell analysis, cell viability and impedance measurements
Contact
Hankinnathankinnat@helsinki.fi- Result · PrequalificationType
- 38000000Main codeLaboratory, optical and precision equipments (excl. glasses)
- 38434540Biomedical equipment38500000Checking and testing apparatus38540000Machines and apparatus for testing and measuring