Search

  • Search


    High-voltage test system

    Kaakkois-Suomen Ammattikorkeakoulu Oy

    High-voltage test system

    1. Competition notice published

      May 26, 7:41 AMMay 26, 2025 7:41 AM
    2. Questions deadline

      Jun 13, 1:00 PMJune 13, 2025 1:00 PM
    3. Tender submission deadline

      Jun 23, 9:00 AMJune 23, 2025 9:00 AM
    4. Opening date

      Jun 23, 9:15 AMJune 23, 2025 9:15 AM
    5. Tender validity period

      Dec 23, 10:00 AMDecember 23, 2025 10:00 AM

    Brief

    Finland: Tenders/Kaakkois-Suomen Ammattikorkeakoulu Oy/High-voltage test system

    Expired

    The competition has expired without a winner being announced.

    Brief

    Laboratorie- og analyseutstyr

    Kaakkois-Suomen Ammattikorkeakoulu Oy needs an AC High-voltage test system for the Electronics 3K-factory in Savonlinna, Finland, with a maximum total value of 500,000 EUR. The system must include an impulse voltage test system for generating full lightning impulse (LI) and AC test voltage against earth, adhering to IEC 60060-1 and IEC 60060-02 standards. Key components include an HV generator/transformer (min. 100 kVA, 100 kV, 50 Hz), an impulse voltage generator (min. 200 kV, 10 kJ total charging energy), and a comprehensive control system. The system must be CE-approved, meet EU safety regulations, and have a minimum 2-year warranty covering all main components and control devices. Offers will be evaluated based on quality and price.

    About the bid

      South-Eastern Finland University of Applied Sciences (Xamk) is purchasing AC High-voltage test system. The test system includes impulse voltage test system for generation of full lightning impulse (LI) and AC test voltage against earth according to this tender documentation. Equipment will be located to the Electronics 3K-factory in Savonlinna. The floor space available for the device in the laboratory is roughly 10m x 10m. South-Eastern Finland University of Applied Sciences (Xamk) asks offers for the Electronics 3K-factory in Savonlinna about an AC High-voltage test system for generation of full lightning impulse voltage (LI) in accordance with IEC 60060-1 and IEC 60060- 02. And AC voltage test against earth according to IEC 60060-1 within a range of approx. 10 % to 100 % of the rated voltage. The complete test system is controlled by the operating device. The control device allows easy operation of HV test system including manual, basic semi-automatic and fully automatic operation modes. Measured data such as voltage and other measurements are displayed, recorded and stored. Main components of the AC High-voltage test system: - HV generator/transformer minimum 100 kVA, 100 kV, 50 Hz - Electronic power supply and regulation - HV measuring divider - Control system with operator device, display, keyboard, remote diagnostics module and Web interface - Control and measuring cables - HV connections and earthing devices - Safety devices, signal lights and emergency STOP button - Operator board for the control and operating equipment System parameters : - Rated output voltage minimum 100 kV - Rated output current minimum 1 A - Rated output power minimum 100 kVA - Frequency 50 Hz - Duty cycle: Continuous operation - Calibration of the test system in accordance IEC 60060-2 - Calibration certificate Main components of the Impulse voltage test system (LI): - Impulse voltage generator with automatic earthing system, minimum 200 kV - Set of resistors for lightning impulses - Charging unit - Control unit - Impulse voltage divider - Transient recorder - Control system with operator device, display, keyboard, remote diagnostics module and Web interface - Control and measuring cables - HV connections and earthing devices - Safety devices, signal lights, horn, emergency STOP button. System parameters: - Cumulative charging voltage minimum 200 kV - Total charging energy 10 kJ - Impulse capacitance 500 nF - Number of stages 2 - Stage charging voltage minimum 100 kV - Calibration of the test system in accordance IEC 60060-2 - Calibration certificate Power supply requirements (mains supply) - 3NPE - Rated voltage 230/400 V - Frequency 50 Hz Some other absolute requirements - The warranty time is min. 2 years, the warranty covers all main components and control devices - The system must fulfill European Union safety regulations and has to be CE-approved and marked

      Contact name
      Nuutti Teräsalmi
      Contact phone
      +358 406373890
      Contact email
      Nuutti.Terasalmi@xamk.fi
      Address
      Patteristonkatu 3 D, 50100 Mikkeli

    Custom Assessment Criteria

    Start a free trial to ask your own questions about the tender and get AI-generated answers.

    Award Criteria

    Qualification requirements

      Found no qualification requirements in the contract notice.

    Previous Contract Winners

    Start a free trial to see who has won similar tenders for this buyer.

    See the full notice

    Contracting authority
    Kaakkois-Suomen Ammattikorkeakoulu Oy
    Title
    High-voltage test system
    Type
    CompetitionPrequalification
    Main code
    38500000Checking and testing apparatus
    Supplemental codes

    No supplemental codes from buyer…

    Location
    Etelä-Savo
    Estimated value
    €500,000.00