Search
  • Search


    Low-flow liquid chromatography ultrahigh-resolution mass spectrometry platform

    Danmarks Tekniske Universitet - DTU

    Low-flow liquid chromatography ultrahigh-resolution mass spectrometry platform

    1. Supplier selection

      Mar 5, 12:00 AMMarch 5, 2026 12:00 AM
    2. Result notice published

      Mar 5, 8:22 AMMarch 5, 2026 8:22 AM
    3. Contract signed

      Mar 20, 12:00 AMMarch 20, 2026 12:00 AM
    4. Change in result

      Mar 25, 7:33 AMMarch 25, 2026 7:33 AM

    Brief

    Denmark: Tenders/Danmarks Tekniske Universitet - DTU/Low-flow liquid chromatography ultrahigh-resolution mass spectrometry platform

    Awarded

    The competition has ended and a winner has been selected.

    Qualification deadline
    Mar 24,Expired
    Award
    Procedure
    Without prior noticeTwo stages
    Agreement
    Buying goods
    Estimated value
    DKK 4.5Mover 1 year

    Brief

    Danmarks Tekniske Universitet - DTU har indgået en aftale med Thermo Electron A/S om at levere en low-flow liquid chromatography ultrahigh-resolution mass spectrometry platform til Københavns omegn, med en varighed på 1 år og en værdi på 4.500.000 DKK. Platformen skal kunne karakterisere små molekyler med kollisionsdissociation og laserbaseret ultraviolet-fotodissociation (UVPD) for multi-trins molekylær fragmentering (MSn) i væskekromatografi tidsskala. Systemet skal have to uafhængige massedetektorer og kunne opløse meget komplekse molekylære blandinger med isotopdetektion ved en million i masseopløsning (ved masse-til-ladning 200) eller højere. Væskekromatografisystemet skal kunne udføre kromatografiske separationer af komplekse blandinger under lav-flow forhold (10-100 nanoliter per minut) og være sømløst integreret med nanoelektrosprayionisering, styret inden for samme softwaremiljø. Specifikke krav inkluderer to atmosfæriske trykioniseringsgrænseflader (HESI og NSI), et nanoflow UHPLC-instrument, der kan operere fra 1 nanoliter per minut til 100 mikroliter per minut ved op til 1500 bar, og et massespektrometer, der kan udføre op til 10 stadier af data-afhængige fragmenteringer (MSn) og har en intra-spektrum dynamisk rækkevidde på mindst 5000. Der deltog 1 leverandør i konkurrencen.

    Laboratorieutstyr og analyseinstrumenter

    Result

    TED
    • Thermo Electron A/S
      Winner
    • Number of bids
      1
    • Contract value
      DKK 4,500,000

    Custom Assessment Criteria

    • Get answers to your bid/no-bid criteria

      Set them up once and Cobrief answers them in every tender

    Will you bid?

    The agent sets up the bid and writes the first draft. Free for 14 days.

    Award Criteria

    • Description

      Technical.

      Source

      No source found in the documents. Check the weight against the tender documents.

    Previous winners

    • Who are you up against?

      The suppliers who have won similar contracts at Danmarks Tekniske Universitet - DTU

    From the notice

    • DTU Sustain is working with environmental forensics and metabolomic investigations to study the fate and occurrence of chemicals and small molecules dispersed into the environment. To be able to make these investigations, DTU wants to procure a low-flow liquid chromatography ultrahigh-resolution mass spectrometry platform, capable of characterizing small molecules with collisional dissociation and laser-based ultraviolet-photodissociation (UVPD) for multi-stage molecular fragmentation (MSn) in liquid chromatography time scale. The mass spectrometer platform must have two independent mass detectors, and capable of resolving very complex molecular mixtures to improve unknown chemical characterization with fine isotope detection at one million in mass resolution (at mass-to-charge 200) or higher. The liquid chromatography system must be able to make chromatographic separations of complex mixtures at low-flow conditions (10-100 nano-liters per minute) and seamlessly integrated with nanoelectrospray ionization and controlled, jointly with themass spectrometer, within the same software environment. In addition, the combined system must have; • Two atmospheric pressure ionisation interfaces; heated electrospray ionisation (HESI) and nano-spray ionisation (NSI). • A nanoflow UHPLC (ultra-high performance liquid chromatography) instrument that can be operated with the ultrahigh-resolution mass spectrometer, and the combined UHPLCHRMS system is operated within the same software environment. • A nanoflow UHPLC instrument capable of operating from 1 nanoliter per minute to 100 microliter per minute in flow rate, and at backpressures up to 1500 bar. • A nanoflow UHPLC instrument that consist of a binary high-pressure gradient pump, splitloop autosampler, an active nanoflow control unit and onboard user interface for immediate operation. • A UHPLC instrument capable of maintaining sample temperature control within 4-40 oC and holding at least 216 sample vials at the same time. • The UHPLC sampler must support a sample capacity of four sample racks and well plates (96 and 384, deep and shallow) without the need for external devices such as plate feeder. • The user interface must provide guided workflow exchange and maintenance procedures. • The mass spectrometer (MS) must be capable of operating at one million or higher in mass resolution at mass-to-charge (m/z) 200 to resolve complex environmental matrices. • A mass spectrometer capable of performing higher-energy collisional dissiciation and ultraviolet photodissociation for multi-stage MSn-fragmentation in liquid chromatography time scale. • A mass spectrometer capable of fragment ion detection in either ion trap or high-resolution analyzer • A mass spectrometer capable of isolating precursor ions with a quadrupole filter with 0.7 FWHM resolution for 50<m/z<1000. • A mass spectrometer that can perform automated iterative data-dependent acquisition in an integrated software solution. • A mass spectrometer that can perform data-dependent acquisition and data-independent acquisition. • A mass spectrometer with three mass analyzers build on quadrupole, linear ion trap, and Orbitrap technology. • A mass spectrometer with two independent mass detectors - one of them based linear ion trap technology - and both detectors must be capable of operating in parallel with each other. • A mass spectrometer with a removable ion sweep cone. • The mass spectrometer must be capable of switching polarities within 25 mili seconds • The mass spectrometer must be able to perform up to 10 stages of data-dependent fragmentations (MSn). • A mass spectrometer with normalized collision energy capability to automatically compensate for the mass dependent energy deposition and provide instrument-to-instrument fragmentation reproducibility. • A mass spectrometer with a data-dependent decision tree logic to automatic determine optimal fragmentation technique and analyzer during the LC run. • The high resolution mass analyzer must at least have an intra-spectrum dynamic range of 5000. • An ultraviolet photodissociation technology using a 213 nm laser architecture that is fully integrated in the mass spectrometer.

    • Contact

      Katrine Freiesleben Petersenkafre@dtu.dk
    • Type
      Result · Prequalification
    • Location
      Københavns omegn
    • Main code
      Mass spectrometer
      38433100
    • 38000000Laboratory, optical and precision equipments (excl. glasses)38400000Instruments for checking physical characteristics38430000Detection and analysis apparatus38433000Spectrometers

    Similar active competitions

    • Danmarks Tekniske Universitet - DTU

      Laboratorieutstyr og analyseinstrumenter

      Triple quadrupole liquid chromatography-mass spectrometry (LC-MS/MS)

      Danmarks Tekniske Universitet - DTU needs a triple quadrupole liquid chromatography-mass spectrometry (LC-MS/MS) system for a maximum total value of 1,200,000 DKK. The system will support quantitative and qualitative analysis of small molecules in research applications, including validation of novel diagnostic and drug-monitoring methods, and will be shared across research groups and faculties. Waters A/S likely has a similar contract today.

      CompetitionDKK 1,200,000
    • Institut Scientifique de Service Public

      Gasskromatografi og analyseinstrumenter

      Marché de fournitures - Acquisition d'un système de chromatographie liquide couplée à un spectromètre de masse à haute résolution (LC-HRMS/MS)

      L'Institut Scientifique de Service Public (Belgique) a besoin d'un système complet de chromatographie liquide ultra haute performance couplée à un spectromètre de masse haute résolution (LC-HRMS) pour une durée d'un an. Ce système est destiné au screening ciblé, suspect et non ciblé, à la quantification HRMS, aux analyses PFAS, aux contaminants émergents, aux pesticides, aux résidus pharmaceutiques et aux matrices environnementales complexes. La fourniture comprend la livraison, l'installation, la qualification, la mise en service, la formation et la maintenance. Le matériel proposé doit être neuf et inclure une chaîne UHPLC, un spectromètre de masse haute résolution (HRMS) avec modes d'ionisation positif et négatif et acquisition MS/MS, ainsi qu'un ensemble informatique et des logiciels d'acquisition et de traitement des données. Une option obligatoire pour un contrat de maintenance préventive avec option corrective ou un contrat de maintenance omnium après la période de garantie d'un an doit être incluse dans l'offre.

      Competition
      Nov 12, 2026(14 days)
    • Technische Universität Dresden, Dezernat Finanzen und Beschaffung, Sachgebiet Zentrale Beschaffung und Anlagenbuchhaltung

      Laboratorieutstyr og analyseinstrumenter

      Hochauflösendes Massenspektrometer

      Die Technische Universität Dresden benötigt die Lieferung und betriebsbereite Übergabe eines hochauflösenden Massenspektrometers, bestehend aus Quadrupol-Massenfilter, Linear-Ionenfalle und hochauflösendem Massenanalysator. Die Lieferung soll in Dresden erfolgen und die Vertragslaufzeit beträgt 2 Monate.

      Competition