Search
  • Search


Switzerland: Tenders/Paul Scherrer Institut (PSI)/Magnet mit horizontaler Feldausrichtung und extrem breitem Strahlzugang für Neutronenstreuexperimente
  1. Competition notice published

    Oct 23, 10:25 PMOctober 23, 2026 10:25 PM
  2. Tender submission deadline

    Dec 22, 9:00 AMDecember 22, 2026 9:00 AM
  3. Tender validity period

    Apr 21, 2027 8:00 AMApril 21, 2027 8:00 AM

Brief

Magnet mit horizontaler Feldausrichtung und extrem breitem Strahlzugang für Neutronenstreuexperimente

Deadline
Dec 22,53 days left
Procedure
OpenSingle stage
Agreement
Buying goods

Brief

Paul Scherrer Institute (PSI) needs a custom high-field magnet system for neutron-scattering research at the Swiss Spallation Neutron Source (SINQ), to be installed in Aargau, Switzerland. The system must provide a maximum horizontal field strength of 6 T and at least 315° of cumulative horizontal beam access, with asymmetric openings allowing use across SINQ instruments. It is to be optimized for intensity mapping with large-area position-sensitive detectors on the CAMEA spectrometer and DMC and ZEBRA diffractometers.

Register interest

Custom Assessment Criteria

  • Get answers to your bid/no-bid criteria

    Set them up once and Cobrief answers them in every tender

Will you bid?

The agent sets up the bid and writes the first draft. Free for 14 days.

Award Criteria

  • Description

    Award criteria

    Source

    No source found in the documents. Check the weight against the tender documents.

Previous winners

  • Who are you up against?

    The suppliers who have won similar contracts at Paul Scherrer Institut (PSI)

From the notice

  • The Paul Scherrer Institute (PSI) plans to purchase a new, globally unique horizontal high-fieldmagnet system with ultra-wide beam access, for use in neutron science research at the Swissnational neutron source (SINQ).The system is envisioned in a manner that uniquely combines a maximum horizontal field strength of 6T, with an ultra-wide beam access in the horizontal plane that cumulatively is more than or equal to 315°. An asymmetric arrangement of magnet openings for the neutron beams access will ensure that the system can be used for any SINQ instrument, yet it is to be optimized specifically for exploiting the intensity mapping capabilities of SINQ instruments with large area position-sensitive detectors, namely the spectrometer CAMEA and the diffractometers DMC and ZEBRA.

  • Contact

    publictenders@psi.ch
  • Type
    Competition
  • Location
    Aargau
  • Main code
    Particle accelerators
    31643000
  • 31630000Magnets

Similar active competitions

  • Paul Scherrer Institut (PSI)

    ADRESS 2.0 Resonant Inelastic X-Ray Scattering instrument

    Paul Scherrer Institut (PSI) needs a new experimental ultra-high-vacuum Resonant Inelastic X-ray Scattering (RIXS) instrument, consisting of a RIXS spectrometer and a RIXS sample chamber, for the soft x-ray beamline ADRESS 2.0 of the Swiss Light Source 2.0 (SLS 2.0). The instrument should be delivered to Aargau, Switzerland. The RIXS spectrometer needs to be designed to allow the possibility of being lifted by air-pads and rotated around the RIXS sample chamber on a granite floor with a range of ≥130 degrees. The ADRESS 2.0 beamline covers an energy range from 250 eV to 1700 eV with variable polarization control. The award criteria are based on quality.

    Competition
    Nov 2, 2026(3 days)
  • ETH Zürich - Abt. Procurement & Export Services

    Laboratorie-, optisk- og presisjonsutstyr

    Scanning electron microscope for imaging and quantitative analysis in geological samples

    ETH Zürich - Abt. Procurement & Export Services needs a new scanning electron microscope (SEM) equipped with a field emission gun, secondary electrons detector (SE) and high-performance backscattered electron detectors (BSE), and a state-of-the-art large area (≥ 100 mm2) energy dispersive spectrometer (EDS) for imaging and quantitative analysis in geological samples. The instrument should have a large chamber to allow a minimum of 3 petrographic thin sections and 6 one-inch epoxy round mounts, and be programmable for automated quantitative EDS analyses lasting over 24 hours. The main goal is to provide precise and accurate quantitative analyses by EDS using a rigorous quantification protocol. The delivery location is Zürich. Offers for panchromatic and/or entry-level monochromatic cathodoluminescence detectors are also welcome. The award criteria are based on quality.

    Competition
    Nov 11, 2026(12 days)
  • Paul Scherrer Institut

    Bygningsarbeid og installasjoner

    PSI PV-Anlagen Contracting Etappe 2

    Das Paul Scherrer Institut benötigt die Planung, Installation und den Betrieb von Photovoltaikanlagen im Kanton Aargau. Die genauen Leistungen sind im Dokument "PSI PV-Anlagen Contracting Etappe 2 Leistungsverzeichnis.pdf" beschrieben. Die Vergabe erfolgt nach Qualitätskriterien.

    Competition
    Nov 5, 2026(6 days)