Microscope for 2-photon multiscale imaging
Laboratorie- og analyseutstyr
Aarhus Universitet has entered into an agreement with Triolab AS for the delivery of an advanced inverted two-photon microscope for in vivo multiscale imaging of biological tissues, to be delivered in Østjylland. The system is required to provide high-speed simultaneous acquisition of at least two to three imaging channels, freely adjustable spectral detection on non-descanned detectors, resonant scanning technology, FLIM functionality, advanced automated imaging workflows, high-resolution with large field of view deep-tissue imaging capabilities, and full compatibility with existing Leica software and equipment. This procurement was awarded without prior publication due to the technical requirement that only the Leica STELLARIS 8 DIVE system, available through Triolab AS, meets all minimum technical specifications, particularly regarding resonant scanning speed, spectral detection, real-time detector optimization, and integration with existing Leica platforms.
Result
- Winner
- Triolab AS
- Number of bids
- 0
- Contract value
- DKK 10,829,707
About the bid
- Contact name
- susanne louise skifter
- Contact phone
- 93521509
- Contact email
- susski@au.dk
- Address
- Nordre Ringgade 1, 8000 Aarhus C
The contract concerns the procurement of an advanced inverted two-photon microscope for in vivo multiscale imaging of biological tissues. The system will support research activities at the Department of Biomedicine, including high-speed calcium imaging, fluorescence lifetime imaging (FLIM), tracking of cellular processes, and deep-tissue imaging in living animal models. The system must also integrate seamlessly with existing microscopy platforms within the department's core facility. Necessity of the Technical Requirements The department's existing two-photon microscope no longer meets current research requirements. The new system must provide high-speed simultaneous acquisition of at least two to three imaging channels, freely adjustable spectral detection on non-descanned detectors (NDD) for optimal fluorophore separation, resonant scanning technology for imaging rapid physiological processes in living tissues, FLIM functionality and advanced automated imaging workflows, high-resolution with large field of view deep-tissue imaging capabilities and full compatibility with existing Leica software and equipment already used in the core facility, thereby ensuring efficient workflows, minimizing user training requirements, and facilitating data analysis. These capabilities are necessary to support the research activities funded through the awarded infrastructure grant and to serve the needs of approximately 200 active users of the facility. Based on the market analysis, it has therefore been concluded that only Leica Microsystems is capable of delivering a system that satisfies the contracting authority's minimum technical requirements. Consequently, the contract is awarded without prior publication of a contract notice due to the absence of competition for technical reasons. Market analysis A market assessment was conducted covering the principal suppliers of inverted two-photon microscopy systems. The assessment demonstrated that while several suppliers could meet certain individual requirements, only the Leica STELLARIS 8 DIVE meets all minimum technical requirements. Specifically, the Leica system is the only solution that combines resonant scanning at the speed required for the intended in vivo applications, freely adjustable spectral detection on non-descanned detectors, real-time optimisation of detector performance during imaging and full integration with existing Leica platforms and analysis software already deployed in the core facility. It has therefore been concluded that only Leica Microsystems purchased from Triolab AS, can deliver a system that satisfies the contracting authority's minimum technical requirements. Consequently, the contract is awarded without prior publication of a contract notice due to the absence of competition for technical reasons.
Custom Assessment Criteria
Start a free trial to ask your own questions about the tender and get AI-generated answers.
Award Criteria
Found no award criteria in the contract notice.
Qualification requirements
Found no qualification requirements in the contract notice.
Previous Contract Winners
Start a free trial to see who has won similar tenders for this buyer.
See the full notice
- Contracting authority
- Aarhus Universitet
- Title
- Microscope for 2-photon multiscale imaging
- Type
- Main code
- Supplemental codes
- Location
- Østjylland
No supplemental codes from buyer…
Supplemental codes added by Cobrief