    Aarhus Universitet has entered into an agreement with Triolab AS for the delivery of an advanced inverted two-photon microscope for in vivo multiscale imaging of biological tissues, to be delivered in Østjylland. The system is required to provide high-speed simultaneous acquisition of at least two to three imaging channels, freely adjustable spectral detection on non-descanned detectors, resonant scanning technology, FLIM functionality, advanced automated imaging workflows, high-resolution with large field of view deep-tissue imaging capabilities, and full compatibility with existing Leica software and equipment. This procurement was awarded without prior publication due to the technical requirement that only the Leica STELLARIS 8 DIVE system, available through Triolab AS, meets all minimum technical specifications, particularly regarding resonant scanning speed, spectral detection, real-time detector optimization, and integration with existing Leica platforms.

    Result

    Winner
    Triolab AS
    Number of bids
    0
    Contract value
    DKK 10,829,707

    About the bid

      The contract concerns the procurement of an advanced inverted two-photon microscope for in vivo multiscale imaging of biological tissues. The system will support research activities at the Department of Biomedicine, including high-speed calcium imaging, fluorescence lifetime imaging (FLIM), tracking of cellular processes, and deep-tissue imaging in living animal models. The system must also integrate seamlessly with existing microscopy platforms within the department's core facility. Necessity of the Technical Requirements The department's existing two-photon microscope no longer meets current research requirements. The new system must provide high-speed simultaneous acquisition of at least two to three imaging channels, freely adjustable spectral detection on non-descanned detectors (NDD) for optimal fluorophore separation, resonant scanning technology for imaging rapid physiological processes in living tissues, FLIM functionality and advanced automated imaging workflows, high-resolution with large field of view deep-tissue imaging capabilities and full compatibility with existing Leica software and equipment already used in the core facility, thereby ensuring efficient workflows, minimizing user training requirements, and facilitating data analysis. These capabilities are necessary to support the research activities funded through the awarded infrastructure grant and to serve the needs of approximately 200 active users of the facility. Based on the market analysis, it has therefore been concluded that only Leica Microsystems is capable of delivering a system that satisfies the contracting authority's minimum technical requirements. Consequently, the contract is awarded without prior publication of a contract notice due to the absence of competition for technical reasons. Market analysis A market assessment was conducted covering the principal suppliers of inverted two-photon microscopy systems. The assessment demonstrated that while several suppliers could meet certain individual requirements, only the Leica STELLARIS 8 DIVE meets all minimum technical requirements. Specifically, the Leica system is the only solution that combines resonant scanning at the speed required for the intended in vivo applications, freely adjustable spectral detection on non-descanned detectors, real-time optimisation of detector performance during imaging and full integration with existing Leica platforms and analysis software already deployed in the core facility. It has therefore been concluded that only Leica Microsystems purchased from Triolab AS, can deliver a system that satisfies the contracting authority's minimum technical requirements. Consequently, the contract is awarded without prior publication of a contract notice due to the absence of competition for technical reasons.

      Contact name
      susanne louise skifter
      Contact phone
      93521509
      Contact email
      susski@au.dk
      Address
      Nordre Ringgade 1, 8000 Aarhus C

    Custom Assessment Criteria

    Start a free trial to ask your own questions about the tender and get AI-generated answers.

    Award Criteria

      Found no award criteria in the contract notice.

    Qualification requirements

      Found no qualification requirements in the contract notice.

    Previous Contract Winners

    Start a free trial to see who has won similar tenders for this buyer.

    See the full notice

    Contracting authority
    Aarhus Universitet
    Title
    Microscope for 2-photon multiscale imaging
    Type
    ResultPrequalification
    Main code
    38000000Laboratory, optical and precision equipments (excl. glasses)
    Supplemental codes

    No supplemental codes from buyer…

    Supplemental codes added by Cobrief

    38510000Microscopes
    38513100Inverted microscopes
    38515200Fluorescent microscopes
    Location
    Østjylland

    Active similar competitions

    • Danmarks Tekniske Universitet - DTU

      Laboratorie-, optisk- og presisjonsutstyr

      Purchase of 5 Fluorescence Microscopes

      Danmarks Tekniske Universitet (DTU) needs to purchase 5 fluorescence microscopes with a maximum total value of 1,400,000 DKK. The equipment should consist of four inverted microscopes with X/Y test tables, capable of visualizing samples using reflected light in fluorescence and bright field. The fluorescence detection system must be able to observe and separate DAPI, FITC, and TRITC fluorophores. The microscopes must be equipped with lenses for optical measurements from 4x to 100x magnification, using cover glass. Three microscopes need to image at 4x and 20x, one at 10x and phase contrast at 20x, and one at 10x and 60x or higher. All microscopes should include a 1.5x optivar lens and allow for mounting a C-mount camera with a 25mm FOV. One microscope must have a motorized X-Y table compatible with Micromanager software.

      CompetitionAug 26, 2026DKK 1,400,000
    • INSERM AUVERGNE, RHONE-ALPES

      Laboratorie-, optisk- og presisjonsutstyr

      Acquisition d'un microscope inversé équipé d’un scanner spinning-disk et d’une fonction lecteur de microplaques (absorbance, fluorescence, luminescence)

      L'INSERM AUVERGNE, RHONE-ALPES a besoin d'un microscope inversé équipé d'un scanner spinning-disk et d'une fonction lecteur de microplaques (absorbance, fluorescence, luminescence) pour une durée de 8 mois. Le microscope sera livré et installé au laboratoire Inserm P4 à Lyon, Rhône, France.

      CompetitionOct 12, 2026
      Nov 15, 2026(17 days)
    • Lietuvos sveikatos mokslų universitetas (PV)

      Laboratorie- og analyseutstyr

      Inversinis mikroskopas (atviras tarptautinis)

      Lietuvos sveikatos mokslų universitetui reikia inversinio mikroskopo, 1 komplekto, kurio maksimali vertė yra 8000 EUR. Sutarties trukmė – 3 mėnesiai. Prekės turi būti pristatytos Kauno apskrityje. UAB "Inospectra" šiandien turi panašią sutartį.

      CompetitionOct 1, 2026
      Nov 3, 2026(5 days)
      €8,000
    • Statsbygg

      Laboratorie- og analyseutstyr

      1105601 UiO Livsvitenskap brukerutstyr. K935.11 Superresolusjon mikroskop

      Statsbygg trenger et invertert super-resolusjonsmikroskop med SMLM, SIM og TIRF modalitet for Livsvitenskapsbygget i Oslo, som skal brukes i et BSL3-laboratorium for studier av patogene bakterier og virus, samt deres interaksjoner med vertsceller og organoider/vev på enkeltcellenivå. Mikroskopet skal muliggjøre høyoppløselig fluorescensmikroskopi av levende mikrober og vert-patogen-interaksjoner, og skal leveres med sceninkubasjonskammer med CO2- og temperaturkontroll, motorisert scene med holdere for objektglass og multiwell-plater, samt to datamaskiner med programvare for mikroskopkontroll, analyse og etterbehandling av bilder. Tildelingskriteriene er kvalitet (65%), totalkostnad (30%) og service (5%). Kvalifikasjonskrav inkluderer dokumentasjon av inntil 3 relevante leveranser utført de siste 3 årene, samt en kort beskrivelse av leverandørens personell og tekniske enheter.

      CompetitionOct 5, 2026
      Nov 9, 2026(11 days)
    • Københavns Universitet

      Laboratorie- og analyseutstyr

      Tissue Organoid Research Infrastructure (TORI)

      Københavns Universitet is planning the procurement of automated cell culture and integrated imaging platforms, including instruments, reagents, pipette tips, and servicing, for three sites.