Pre-qualification for Low Voltage Switchgears to Data Center Heat Pump plants project in Espoo and Kirkkonummi
Published deadline passed
The published deadline has passed. For multi-stage competitions a later tender deadline may still apply — check the notice or portal for the current phase.
- Qualification deadline
- Jan 15, 2024Expired
- Procedure
- Competitive dialogueTwo stages
- Agreement
- Buying goodsover 3 years
Brief
Scope of supply consists of the following complete low voltage switchgear (690 VAC and 400 VAC) and low voltage busducts. The final scope and options will be announced later in the Tendering phase: KOL- Heat pump plant Kolabacken, Kirkkonummi: •about 7 pieces, 690 V AC low voltage switchgears with following preliminary main ratings and features: •Rated currents: 1600…4000 A, about 50… 63 kA(1s) •Voltage system: TN-S, without neutral distribution •Installation location: Indoor •about 6 pieces, 400 V AC low voltage switchgears with following preliminary main ratings and features: •Rated currents: 400…4000 A, about 50… 63 kA(1s)•Voltage system; TN -S •Installation location: Indoor •about 12 pieces low voltage busducts (690 VAC and 400 VAC) following preliminary main ratings and features: •Rated currents: 1600…4000 A, about 50… 63 kA(1s) •Voltage system; TN-S, TN •Installation location: Indoor HEP- Heat pump plant Hepokorpi, Espoo: •about 6 pieces, 690 V AC low voltage switchgears with following preliminary main ratings and features: •Rated currents: 1600…4000 A, about 50… 63 kA(1s) •Voltage system: TN-S, without neutral distribution •Installation location: Indoor •about 5 pieces, 400 V AC low voltage switchgears with following preliminary main ratings and features: •Rated currents: 400…4000 A, about 50… 63 kA(1s) •Voltage system; TN -S •Installation location: Indoor •about 11 pieces, low voltage busducts (690 VAC and 400 VAC) following preliminary main ratings and features: •Rated currents: 1600…4000 A, about 50… 63 kA(1s)•Voltage system; TN-S, TN •Installation location: Indoor Including the following equipment, structures and services: •LV- switchgears, busducts and equipment with all necessary structures, components, and materials, •control, protection, monitoring, metering etc. equipment and devices with necessary auxiliaries, •all necessary protection devices, circuit breakers, fuses etc. of switchgears and auxiliaries, •switchgears internal primary and secondary cabling and wiring with all necessary materials and auxiliaries, •necessary earthing materials and terminals within cabinets, units and switchgears, •all rating plates and equipment nameplates, •all earthing temporary devices etc. as specified in specification, •transportation of switchgears and equipment to construction site, •mechanical installation of deliverables to electrical rooms at construction site, •site tests after installation with all necessary reports, •operation and maintenance manuals and instructions, •documentation, •spare parts.
Elektrisk utstyr og belysning
Custom Assessment Criteria
Get answers to your bid/no-bid criteria
Set them up once and Cobrief answers them in every tender
Will you bid?
The agent sets up the bid and writes the first draft. Free for 14 days.
Award Criteria
Source
No source found in the documents. Check the weight against the tender documents.
Previous winners
Who are you up against?
The suppliers who have won similar contracts at Fortum Power and Heat Oy
From the notice
Scope of supply consists of the following complete low voltage switchgear (690 VAC and 400 VAC) and low voltage busducts. The final scope and options will be announced later in the Tendering phase: KOL- Heat pump plant Kolabacken, Kirkkonummi: •about 7 pieces, 690 V AC low voltage switchgears with following preliminary main ratings and features: •Rated currents: 1600…4000 A, about 50… 63 kA(1s) •Voltage system: TN-S, without neutral distribution •Installation location: Indoor •about 6 pieces, 400 V AC low voltage switchgears with following preliminary main ratings and features: •Rated currents: 400…4000 A, about 50… 63 kA(1s)•Voltage system; TN -S •Installation location: Indoor •about 12 pieces low voltage busducts (690 VAC and 400 VAC) following preliminary main ratings and features: •Rated currents: 1600…4000 A, about 50… 63 kA(1s) •Voltage system; TN-S, TN •Installation location: Indoor HEP- Heat pump plant Hepokorpi, Espoo: •about 6 pieces, 690 V AC low voltage switchgears with following preliminary main ratings and features: •Rated currents: 1600…4000 A, about 50… 63 kA(1s) •Voltage system: TN-S, without neutral distribution •Installation location: Indoor •about 5 pieces, 400 V AC low voltage switchgears with following preliminary main ratings and features: •Rated currents: 400…4000 A, about 50… 63 kA(1s) •Voltage system; TN -S •Installation location: Indoor •about 11 pieces, low voltage busducts (690 VAC and 400 VAC) following preliminary main ratings and features: •Rated currents: 1600…4000 A, about 50… 63 kA(1s)•Voltage system; TN-S, TN •Installation location: Indoor Including the following equipment, structures and services: •LV- switchgears, busducts and equipment with all necessary structures, components, and materials, •control, protection, monitoring, metering etc. equipment and devices with necessary auxiliaries, •all necessary protection devices, circuit breakers, fuses etc. of switchgears and auxiliaries, •switchgears internal primary and secondary cabling and wiring with all necessary materials and auxiliaries, •necessary earthing materials and terminals within cabinets, units and switchgears, •all rating plates and equipment nameplates, •all earthing temporary devices etc. as specified in specification, •transportation of switchgears and equipment to construction site, •mechanical installation of deliverables to electrical rooms at construction site, •site tests after installation with all necessary reports, •operation and maintenance manuals and instructions, •documentation, •spare parts.
Contact
jarno.vainio@fortum.com- Competition · PrequalificationType
- 31600000Main codeElectrical equipment and apparatus