Search
  • Search


    Procurement of synchrotron microtomography scanning of fossils

    Uppsala universitet

    Procurement of synchrotron microtomography scanning of fossils

    1. Supplier selection

      Feb 27, 12:00 AMFebruary 27, 2026 12:00 AM
    2. Result notice published

      Feb 27, 8:16 AMFebruary 27, 2026 8:16 AM

    Brief

    Sweden: Tenders/Uppsala universitet/Procurement of synchrotron microtomography scanning of fossils

    Published deadline passed

    The published deadline has passed. For multi-stage competitions a later tender deadline may still apply — check the notice or portal for the current phase.

    Qualification deadline
    Feb 26,Expired
    Procedure
    Without prior noticeTwo stages
    Agreement
    Buying services

    Brief

    Uppsala universitet har till avsikt att ingå en avtal med European Synchrotron Radiation Facility i Grenoble för att utföra synkrotronmikrotomografisk skanning av fossil. Tjänsterna ska levereras i Grenoble och avtalet har ett uppskattat värde på 2 miljoner svenska kronor. Specifika krav inkluderar skanning vid upplösningar från cirka 40 µm ner till 0,7 µm, med möjlighet till multiskalaskanning på ett enda prov utan demontering. Det krävs också att synkrotronstrålen är tillräckligt kraftfull för att penetrera bergprover med minst 20-30 cm diameter, vilket kräver en stråle med en minimienergi på minst 200 KeV.

    Foto- og dokumentasjonstjenester

    Result

    TED
    • European Synchrotron Radiation Facility
      Winner
    • Number of bids
      0
    • Contract value
      Not stated

    Custom Assessment Criteria

    • Get answers to your bid/no-bid criteria

      Set them up once and Cobrief answers them in every tender

    Will you bid?

    The agent sets up the bid and writes the first draft. Free for 14 days.

    Previous winners

    • Who are you up against?

      The suppliers who have won similar contracts at Uppsala universitet

    From the notice

    • Uppsala University intends to sign an agreement with European Synchrotron Radiation Facility in Grenoble for performing synchrotron microtomography scanning of fossils. Background and motivation Synchrotron microtomography scanning of fossils is used to visualise the internal three-dimensional structure of the fossils, allowing these to be studied without damage. The technique is central to the research of the Programme of Evolution and Development and underlies a large proportion of their publications. Imaging needs to be done at a range of resolutions from approximately 40 µm (for morphology large objects) down to 0.7 µm (for detailed examination of histology), with an option to carry out multi-scale scanning on one specimen without dismounting it from the apparatus. In order for the research to be completed successfully it is essential to obtain the highest possible image quality, with sharp outlines, no beam-hardening artefacts (which artificially brighten the edges of the scanned object), and maximum contrast between bone and surrounding rock. This can only be achieved by propagation phase contrast synchrotron microtomography; conventional microtomography using non-synchrotron x-ray sources does not produce adequate results. The differences can be summarised as follows: · The difference between synchrotron radiation and conventio-nal x-rays is similar to that between a laser and an ordinary light source such as a torch: synchrotron x-rays are monochromatic (i.e. just one wave length and energy), coherent (the waves all move together in phase), and perfectly parallel, whereas a conventional x-ray source produces many wavelengths and energies, which are not coherent, and the paths of the photons diverge in all directions. The result is that conventional x-ray scans produce what are known as "beam-hardening effects", whereby low-energy photons are absorbed selectively. The visual conse-quence is bright foggy edges to the blocks containing the specimens, which obscure the contents within. Synchrotron scans are much sharper and lack beam-hardening effects. · Because synchrotron x-rays are monochromatic and coherent, they can be used for detection of propagation phase contrast. This means detecting not just the absorption of x-rays by the specimen (which is all you can do with a conventional x-ray source), but also the refraction effects created by the structures inside the specimen. The refraction causes photons to diverge from their original path, an effect that becomes more pronounced the further the photons travel after passing through the specimen before hitting the detector; this is the "propagation distance". Because a synchrotron scan detects both absorption and refraction, its ability to distinguish different materials (such as bone embedded in rock) is several thousand times greater than that of a conventional x-ray scan with the same resolution. It is commonplace for a synchrotron scan to show a wealth of internal anatomical structure where a conventional x-ray scan revealed nothing at all. Synchrotron microtomography is thus essential. In addition, the synchrotron beam needs to be powerful enough to penetrate rock specimens of at least 20-30 cm diameter, which requires a beam with a minimum energy of at least 200 KeV (kilo electron volts), and at the same time wide enough to be usable on specimens of that size. This is limiting, because mot synchrotrons produce beams of smaller size and/or lower energy. For example, MAX IV reaches a maximum energy of no more than 30 KeV and is thus no use to us. Alternatives There are many synchrotrons in the world, but only a few offer tomography and only two, ESRF (European Synchrotron Radiation Facility, in Grenoble) and SLS (Swiss Light Source, located between Zürich and Basel), have specialised tomographic beamlines suitable for palaeontology. The TOMCAT beamline at SLS is excellent for small specimens but cannot manage objects more than about one-tenth the size we require. By contrast, ESRF Beamline BM18 has been built specifically for performing multi-scale propagation phase contrast microtomography on large specimens, and has by far the largest specimen stage, widest beam, and longest propagation distance in the world. Beamline BM05, operating in tandem with BM18 under the same management team, is specialised for very high resolution. No other tomographic facility comes close to matching these capabilities. Decision On the circumstances above, it is decided to procure synchrotron microtomography scanning of fossils from ESRF in Grenoble, by negotiated procedure without prior advertising on the basis of technical exclusivity. The contract value is estimated to be 2 MSek.

    • Contact

      info@uu.se
    • Type
      Result · Prequalification
    • Location
      Uppsala län
    • Main code
      Specialised photography services
      79961300
    • 79961000Photographic services

    Similar active competitions

    • Uppsala universitet

      Laboratorieutstyr og analyseinstrumenter

      X­ray System

      Uppsala universitet needs an X-ray System to be delivered in Uppsala län, with a maximum total value of 4 million SEK. Carl Zeiss AB likely has a similar contract today.

      Competition
      Nov 10, 2026(12 days)
      SEK 4,000,000
    • Uppsala universitet

      Laboratorie- og analyseutstyr

      Brillouin Microscopy system

      Uppsala University needs a Brillouin microscopy system for delivery in Uppsala County, with a maximum total contract value of SEK 3.5 million.

      Competition
      Nov 24, 2026(26 days)
      SEK 3,500,000
    • Kungliga Tekniska högskolan

      Laboratorie-, optisk- og presisjonsutstyr

      EDS and EBSD attachment to a field-emission scanning electron microscope

      Kungliga Tekniska högskolan needs an integrated system for energy-dispersive X-ray spectroscopy (EDS) and electron backscatter diffraction (EBSD), to be mounted on the existing JEOL JSM-7800F field-emission scanning electron microscope (FE-SEM) at the Hultgren Laboratory, with a maximum total value of 170,000 EUR. The goods are to be delivered in Stockholms län.

      Competition
      Nov 2, 2026(4 days)
      €170,000