Find

  • All tenders
All tenders: Ireland/Medite Europe DAC/Supply of New Air Compressors and New Blowers for WWTP at Medite Europe DAC '25

Supply of New Air Compressors and New Blowers for WWTP at Medite Europe DAC '25

Expired

The competition has expired without a winner being announced.

Deadline
Jun 3, 2025Expired
Procedure
OpenSingle stage
Agreement
Buying goods
Estimated value
€180K

Brief

MEDITE Europe DAC requires the supply and equipment commissioning of New Air-Cooled Compressors (2 no.) and New Blowers in WWTP (2 no.). Please note NO installation will be required and the decommissioning and the removal of the existing compressors and blowers will be undertaken by Medite Europe DAC. Background The plant is in operation for 24 hours per day, 7 days per week and 50 weeks per year. A reliable supply of compressed air is absolutely essential to our processes. Also, a reliable supply of air via blowers is absolutely essential to the biological life in WWTP plant. A recent evaluation by our Energy Partner EM3 of our existing compressors and blowers in WWTP - has highlighted based on high run hours greater than 100,000 hours that four key assets are now recommended for replacement at Medite. There are four compressors in main compressor room, Kaeser 1 VSD, Kaeser 2 FS, Kaeser 3 FS, Kaeser 4 FS in existing compressor room. Desired usage for four air cooled compressors is three in service (two fixed and variable speed controlling)/one fixed speed left off in standby mode. There are two existing blowers (of two no.) in WWTP also require to be replaced. Therefore, the following tender requirements to market in parallel is required as one overall supply package: 1) Supply of two new fixed speed air-cooled compressors (to replace two fixed speed air-cooled compressors no. 2 + no. 3 of the four no. existing Kaeser compressors). 2) Supply of two new screw blowers in WWTP area of plant to replace two existing blowers. The air demand (of the main system) at present has been measured as maximum capacity of 6,120 m3/hour of compressed air via three (fourth back-up) Kaeser screw compressors (Three duty/One Standby is desired working arrangement). Hence, two new fixed speed compressors must deliver at minimum 4,080 m3/hour to peak at 4,500 m3/hour at supply pressure of 7.4 bar(g) with a mean demand of 4,100 m3/hour as shown below in recent compressed air mapping study by EM3 for Medite: Requirements • Please provide proposals for two compressor units fixed speed at 7.5 bar(g). • These two machines will have fixed speed drive motors to meet the base load. •All machines must be CE compliant •The compressor packages with air cooled oil injected rotary screw units from the vendors standard product line and will include the following equipment: •Air end and drive arrangement •Inlet filter •Safety valves •Capacity controls for fixed speed units •Discharge check valve •Base plate with anti-vibration mountings •Oil cooler, filtration and separation system •After cooler with zero loss electronic condensate drain valve •Cooling fan and motor (if required) •High efficiency motors •Variable speed drive and controller for variable unit •Starter •Control panel with standard readouts and alarms and trips •All to be installed within an acoustic cabinet that has connections for ducting for inlet and exhaust air streams. •All condensate drains to be of the electronic zero loss type. Compressor Control • An electronic control system is to be supplied that will enable two compressor units to be controlled to ensure that the VSD unit on Kaeser No. 1 VSD is always used as control unit whatever the demand. The controller will provide close pressure control within 0.1bar irrespective of the demand. • The control system must be capable of interfacing with the factory BMS that will show the duty compressor situation and the power being consumed by the compressors. The power consumption will be data logged to enable electronic records to be kept. • All electrics to be to suit site 400v/3ph/50hz for main motors and 110v/1ph/50hz for control. • All performance criteria for flow and power consumption to be quoted in accordance with the CAGI/Pneurop PN2CPTC2 protocol. **** Please see tender document for full and complete scope of works.****

Industrial machinery

Register interest

Previous winners

  • Who are you up against?

    The suppliers who have won similar contracts at Medite Europe DAC

Will you bid?

The agent sets up the bid and writes the first draft. Free for 14 days.

From the notice

  • MEDITE Europe DAC requires the supply and equipment commissioning of New Air-Cooled Compressors (2 no.) and New Blowers in WWTP (2 no.). Please note NO installation will be required and the decommissioning and the removal of the existing compressors and blowers will be undertaken by Medite Europe DAC. Background The plant is in operation for 24 hours per day, 7 days per week and 50 weeks per year. A reliable supply of compressed air is absolutely essential to our processes. Also, a reliable supply of air via blowers is absolutely essential to the biological life in WWTP plant. A recent evaluation by our Energy Partner EM3 of our existing compressors and blowers in WWTP - has highlighted based on high run hours greater than 100,000 hours that four key assets are now recommended for replacement at Medite. There are four compressors in main compressor room, Kaeser 1 VSD, Kaeser 2 FS, Kaeser 3 FS, Kaeser 4 FS in existing compressor room. Desired usage for four air cooled compressors is three in service (two fixed and variable speed controlling)/one fixed speed left off in standby mode. There are two existing blowers (of two no.) in WWTP also require to be replaced. Therefore, the following tender requirements to market in parallel is required as one overall supply package: 1) Supply of two new fixed speed air-cooled compressors (to replace two fixed speed air-cooled compressors no. 2 + no. 3 of the four no. existing Kaeser compressors). 2) Supply of two new screw blowers in WWTP area of plant to replace two existing blowers. The air demand (of the main system) at present has been measured as maximum capacity of 6,120 m3/hour of compressed air via three (fourth back-up) Kaeser screw compressors (Three duty/One Standby is desired working arrangement). Hence, two new fixed speed compressors must deliver at minimum 4,080 m3/hour to peak at 4,500 m3/hour at supply pressure of 7.4 bar(g) with a mean demand of 4,100 m3/hour as shown below in recent compressed air mapping study by EM3 for Medite: Requirements • Please provide proposals for two compressor units fixed speed at 7.5 bar(g). • These two machines will have fixed speed drive motors to meet the base load. •All machines must be CE compliant •The compressor packages with air cooled oil injected rotary screw units from the vendors standard product line and will include the following equipment: •Air end and drive arrangement •Inlet filter •Safety valves •Capacity controls for fixed speed units •Discharge check valve •Base plate with anti-vibration mountings •Oil cooler, filtration and separation system •After cooler with zero loss electronic condensate drain valve •Cooling fan and motor (if required) •High efficiency motors •Variable speed drive and controller for variable unit •Starter •Control panel with standard readouts and alarms and trips •All to be installed within an acoustic cabinet that has connections for ducting for inlet and exhaust air streams. •All condensate drains to be of the electronic zero loss type. Compressor Control • An electronic control system is to be supplied that will enable two compressor units to be controlled to ensure that the VSD unit on Kaeser No. 1 VSD is always used as control unit whatever the demand. The controller will provide close pressure control within 0.1bar irrespective of the demand. • The control system must be capable of interfacing with the factory BMS that will show the duty compressor situation and the power being consumed by the compressors. The power consumption will be data logged to enable electronic records to be kept. • All electrics to be to suit site 400v/3ph/50hz for main motors and 110v/1ph/50hz for control. • All performance criteria for flow and power consumption to be quoted in accordance with the CAGI/Pneurop PN2CPTC2 protocol. **** Please see tender document for full and complete scope of works.****

  • Contact

    John.Browne@mdfosb.com
  • Type
    Competition
  • Location
    Dublin
  • Main code
    Air compressors
    42123400
  • 42123000Compressors42123410Mounted air compressors42124330Parts of air compressors

Similar active competitions

  • Gas Networks Ireland

    Industrial machinery

    25/027 - Qualification System for the Provision Of Electric Drive Compressor Packages

    Gas Networks Ireland needs electric drive compressor packages, including the compressor unit, electric motor, ancillary systems, emergency shutdown system, and integration support. The scope includes the physical compressor, electric motor, variable frequency drive (if used), coupling, local instrumentation and control system, lubrication system, cooling system, start-up and shutdown systems, and safety systems. The award criteria are Price and Quality.

    Qualification system
    Oct 30, 2035(100+ days)
  • Veiligheidsregio Kennemerland

    Construction machinery and equipment

    Compressor Veiligheidsregio Kennemerland

    Veiligheidsregio Kennemerland heeft behoefte aan de levering van compressoren, een luchtkwaliteitsmeter en een CO2-filtersysteem voor haar test- en vulactiviteiten voor ademluchtapparatuur, met een maximale totale contractwaarde van 260.000 EUR over 4 jaar. De levering en integratie vinden plaats in de centrale ademluchtwerkplaats van Veiligheidsregio Kennemerland in de agglomeratie Haarlem. De aanbesteding omvat tevens testen, keuring en (her)certificering conform geldende wet- en regelgeving, evenals service en onderhoud van de geleverde componenten en het integrale systeem. Dräger Nederland B.V. heeft vandaag een vergelijkbaar contract. De gunningscriteria zijn Installatieplan (40%), Service en Onderhoudsplan (40%) en Ingevuld Prijzenblad (20%).

    Competition
    Dec 14, 2026(15 days)
    €260,000
  • HEP-Proizvodnja d.o.o.

    Industrial machinery

    Zamjena kompresora sustava odvodnje, hidraulične regulacije crpki-turbina, kompresorske stanice i protupožarne zaštite transformatora u RHE Velebit

    HEP-Proizvodnja d.o.o. treba zamjenu kompresora sustava odvodnje, hidraulične regulacije crpki-turbina, kompresorske stanice i protupožarne zaštite transformatora u RHE Velebit, u Zadarskoj županiji. Nabava obuhvaća isporuku robe i traje 3 godine, uz maksimalnu ukupnu vrijednost od 3.253.288 eura; postupak je otvoren. Ponude se ocjenjuju prema cijeni (90%) i jamstvenom roku za isporučenu i ugrađenu robu (10%). Kvalifikacijski uvjeti obuhvaćaju upis u odgovarajući registar, reference na tražene isporuke te odgovarajuće obrazovne i stručne kvalifikacije.

    Competition
    Dec 9, 2026(10 days)
    €3,253,288