Raman Microscope for DTU Chemistry
Laboratorieutstyr og analyseinstrumenter
Danmarks Tekniske Universitet - DTU has entered into an agreement with Horiba Europe GmbH for the delivery of one complete high-resolution confocal Raman microscopy and spectroelectrochemical characterization system, including all associated hardware, software, accessories, installation, commissioning, training, and warranty, to the Copenhagen area. The system, with a duration of 1 year, will support research and education activities within catalysis, electrochemistry, materials science, energy conversion, sustainable fuels, and chemical synthesis. It must provide high-sensitivity Raman spectroscopy and microscopy with high spectral and spatial resolution, support characterization of various materials and interfaces, and enable investigation of reaction intermediates and dynamic processes. Specific requirements include automated operation, multiple excitation wavelengths (approx. 532 nm, 633 nm, and 785 nm), low-noise detector technology for weak Raman signals and time-resolved measurements, ultra-low-frequency vibrational information (down to 10 cm-1), automated Raman mapping and hyperspectral imaging with micrometre-scale spatial resolution, and integrated spectroelectrochemical measurement capability with electrochemical cells for operando measurements.
Result
- Winner
- HORIBA Europe GmbH
- Number of bids
- 0
- Contract value
- €418,298
About the bid
- Contact name
- Anna Storch
- Contact phone
- +45 999999
- Contact email
- aasst@dtu.dk
- Address
- Anker Engelunds Vej 1, 2800 Kgs. Lyngby
The Technical University of Denmark (DTU) intends to acquire one complete high-resolution confocal Raman microscopy and spectroelectrochemical characterization system, including all associated hardware, software, accessories, installation, commissioning, training, and warranty. The system will support research and education activities within catalysis, electrochemistry, materials science, energy conversion, sustainable fuels, and chemical synthesis. The primary purpose is to enable advanced in situ and operando characterization of functional materials, catalyst surfaces, and catalytic interfaces under realistic operating conditions, including electrochemical environments, elevated temperatures, controlled gas atmospheres, liquid-phase operation, and flow conditions. The instrument shall provide high-sensitivity Raman spectroscopy and microscopy with high spectral and spatial resolution. The system must support characterization of solids, liquids, heterogeneous materials, catalyst surfaces, thin films, nanostructured materials, powders, and solid–liquid and solid–gas interfaces. The equipment shall further enable investigation of reaction intermediates, catalyst transformations, phase transitions, adsorbates, reaction microenvironments, and dynamic processes occurring during electrochemical and catalytic reactions. The system shall include a confocal Raman microscope with automated operation, high-resolution spectroscopic capabilities, motorized sample positioning, automated focusing, Raman mapping and imaging functionality, and support for multiple excitation wavelengths covering the visible and near infrared spectral range, including excitation wavelengths of approximately 532 nm, 633 nm, and 785 nm. The system must be capable of performing both point measurements and spatially resolved Raman imaging of heterogeneous samples with automated data acquisition. The acquisition shall include low-noise detector technology suitable for weak Raman signals, time resolved measurements, and quantitative analysis of both Stokes and anti-Stokes Raman scattering. The system shall provide access to ultra-low-frequency vibrational information (down to 10 cm-1) relevant for studying structural changes, lattice dynamics, catalyst phase transformations, interfacial species, adsorption phenomena, and local temperature effects at catalytic interfaces. The instrument shall further enable simultaneous investigation of chemical composition, structural dynamics, and local thermal phenomena under operating conditions through acquisition of both Stokes and anti-Stokes Raman spectra. The system shall support automated Raman mapping and hyperspectral imaging of heterogeneous samples with micrometre-scale spatial resolution and high positional accuracy. The system must enable investigation of catalyst heterogeneity, dynamic restructuring processes, spatial distributions of reaction intermediates, and structure–activity relationships during operation. The system shall support time-resolved and operando measurements through direct integration be-tween electrochemical instrumentation and the spectroscopic platform, enabling synchronized electrochemical control and Raman data acquisition. The system shall allow simultaneous monitoring of electrochemical parameters and spectroscopic responses during catalytic operation and provide direct correlation between catalyst state, reaction intermediates, local temperature, and electrochemical performance. The equipment shall be suitable for spectroelectrochemical investigations of electro-chemical reactions and interfaces under controlled operating conditions. The acquisition shall further include dedicated spectroelectrochemical accessories, electrochemical cells suitable for operando measurements, flow-compatible accessories, control software, data acquisition and processing software, computer workstation, vibration-isolated installation platform, and all components necessary for full operation of the instrument. The system shall be designed for long-term research use and support future expansion through additional optical components, detectors, excitation sources, analytical modules, environmental cells, and experimental accessories. Scope of supply: • One complete confocal Raman spectroscopy and microscopy system. • High-resolution spectrometer and detector system. • Multiple excitation wavelengths. • Automated sample positioning, focusing, and mapping capabilities. • Raman imaging and hyperspectral mapping functionality. • Ultra-low-frequency Raman measurement capability. • Stokes and anti-Stokes Raman measurement capability. • Integrated spectroelectrochemical measurement capability. • Electrochemical cell and associated accessories for operando measurements. • Instrument control, acquisition, synchronization, analysis, and visualization software. • Computer workstation and control electronics. • Optical table or equivalent vibration-isolated installation platform. • Installation, commissioning, training, documentation, and warranty. Quantity: One complete integrated Raman microscopy and spectroelectrochemical characterization system.
Custom Assessment Criteria
Start a free trial to ask your own questions about the tender and get AI-generated answers.
Award Criteria
Found no award criteria in the contract notice.
Qualification requirements
Found no qualification requirements in the contract notice.
Previous Contract Winners
Start a free trial to see who has won similar tenders for this buyer.
See the full notice
- Contracting authority
- Danmarks Tekniske Universitet - DTU
- Title
- Raman Microscope for DTU Chemistry
- Type
- Main code
- Supplemental codes
- Location
- Københavns omegn
- Duration
- 1 year
No supplemental codes from buyer…