Supplier qualification system for HVDC Converter substations
Cancelled
The competition has been cancelled.
- Qualification deadline
- Apr 23,Expired
- Procedure
- With negotiationTwo stages
- Agreement
- Buying goods
Brief
Energinet Eltransmission A/S intends to establish a Supplier Qualification System for the procurement of HVDC converters, HVDC- and HVAC-substations, primarily for interconnector and offshore wind energy projects like the Bornholm Energy Island project. The scope of work for suppliers may cover development, design, engineering, procurement, manufacturing, transportation, delivery, construction, installation, testing, commissioning, maintenance, and documentation of HVDC and HVAC installations. HVDC installations should be based on VSC-MMC technology in a half-bridge arrangement, arranged as a bipolar system with Dedicated Metallic Return (DMR), have a transmission capacity range of approximately 1.2 to 2 GW, be capable of absorbing or generating reactive power independently from active power, and be rated for a DC voltage level of ±525 kV. The offshore AC substations will connect offshore wind parks and supply the local grid, and deliverables may also include onshore HVAC substations and a coordinated control system.
Elektrisk infrastruktur og veibelysning
Result
- Reason for cancellationAnnet
- 5Number of bids
Custom Assessment Criteria
Get answers to your bid/no-bid criteria
Set them up once and Cobrief answers them in every tender
Will you bid?
The agent sets up the bid and writes the first draft. Free for 14 days.
Previous winners
Who are you up against?
The suppliers who have won similar contracts at Energinet Eltransmission A/S
From the notice
Energinet and 50 Hertz intends to establish a Supplier Qualification System (“SQS”) for the procurement of HVDC converters, HVDC- and HVAC-substations in connection to the converters. The SQS is mainly intended for interconnector and offshore wind energy related projects such as the Bornholm Energy Island project. In the following, the requirements for a typical project are outlined. Deviations may, however, occur during the lifespan of the SQS. The scope of works of the supplier may cover development, design, engineering, relevant studies and reports, procurement, manufacturing, packaging, transportation, delivery, construction, installation, testing, commissioning, maintenance and documentation of HVDC and HVAC installations. HVDC installations may include: 1. The offshore and/or onshore converters (together ‘the Converters’) for the HVDC Substations and in particular: a. the primary systems b. the secondary systems including black start diesel generators The HVDC substations should 1. be based on VSC-MMC technology, using MMC Building Blocks in a half-bridge arrangement. 2. be arranged as a bipolar system with Dedicated Metallic Return (DMR) 3. have a transmission capacity range from approximately 1,2 to 2 GW 4. have the capability to absorb or generate reactive power independently from the active power (as further specified in each tender) 5. be rated for a DC voltage level of ±525 kV The HVDC offshore converter stations may, amongst other things, include a DC switchyard (the offshore DC switchyard) that: In the following, the requirements for a typical project are outlined. Deviations may, however, occur during the lifespan of the SQS. The scope of works of the supplier may cover development, design, engineering, relevant studies and reports, procurement, manufacturing, packaging, transportation, delivery, construction, installation, testing, commissioning, maintenance and documentation of HVDC and HVAC installations. HVDC station installations may include: 1. The offshore and/or onshore converters (together ‘the Converters’) for the HVDC Substations and in particular: a. the primary systems (AC and DC) b. the secondary systems including but not limited to control and protection systems, black start diesel generators, auxiliary and ancillary systems The HVDC substations should 1. be Voltage Source Converter (VSC), which must be realised as a multi-level converter half-bridge arrangement. 2. be arranged as a bipolar system with Dedicated Metallic Return (DMR) 3. have a transmission capacity range from approximately 1,2 to 2 GW 4. have the capability to absorb or generate reactive power independently from the active power (as further specified in each tender) 5. be rated for a DC voltage level of ±525 kV The HVDC converter stations may, amongst other things, include a DC switchyard (the DC switchyard) that: 1. Should have the necessary components to connect and disconnect any combination of the HVDC converter stations of the respective tender under load. 2. Should be prepared so that future expansions can be carried out concurrently with the existing HVDC links being in normal operation. Brief reduction of current in a single pole at a time is allowed. The offshore AC substations will accommodate connection of offshore wind park connection and supply the local grid. The deliverables may include onshore HVAC substations. Further, the deliverables may include a coordinated control system for the overall project’s system. Finally, the deliverables may include installation, test and subsequent maintenance in connection with the above.Main features of the procedureEstablishing a supplier qualification system.
Contact
Procurement - Aprocurement@energinet.dk- Result · PrequalificationType
- 31170000Main codeTransformers
- 31200000Electricity distribution and control apparatus45232220Substation construction work45232221Transformer substation45317200Electrical installation work of transformers